CS1001 Analog Probe

The CS1001 Analog probe is a switchable 1x /10x 250 MHz oscilloscope probe.

Specifications:

Item Position x 1 Position x 10
Attenuation Ratio 1:1 10:1
Bandwidth DC to 6 MHz DC to 250 MHz
Rise Time 58 ns 2.3 ns
Input Resistance 1 MΩ 10 MΩ
Input Capacitance Approx 67 pF Approx 17 pF
Compensation Range   10-35 pF
Working Voltage 600V DC incl peak AC , derated to 50V at 10MHz and 10V at 100 MHz.
Safety Meets IEC1010-1 Cat 1.
Cable Length 1.2 m

Accessories that are included with probe are:Channel Identifier Clip, Sprung Hook, Ground lead, Insulating Tip, Adjusting Tool, Measuring Tip, Sprung Earth Tip.

CS1002 Analog Probe

The CS1002 Analog probe is a 100x 250 MHz oscilloscope probe.

Specifications:

Item Performance
Attenuation Ratio 1:100
Bandwidth DC to 250 MHz
Rise Time 1.4 ns
Input Resistance 100 MΩ
Input Capacitance 5.5 pF
Compensation Range 10 to 35 pF
Working Voltage Cat II:1.5kV
Safety Meets IEC1010-1 Cat II.
Cable Length 1.3 m

Accessories that are included with probe are:Channel Identifier Clip, Sprung Hook, Ground lead, Insulating Tip, Adjusting Tool, Measuring Tip, Sprung Earth Tip.

CS1003 Analog Probe

The CS1003 Analog probe is a 1000x 50 MHz oscilloscope probe.

Specifications:

Item Performance
Attenuation Ratio 1:1000
Bandwidth DC to 50 MHz
Rise Time <7 ns
Input Resistance 100MΩ
Input Capacitance Approx 3 pF
Compensation Range 5pF to 50pF
Working Voltage DC:1.5kV; AC Pulse: 30kV p-p; Sine Wave:10kV rms
Safety Meets IEC1010-1 Cat 1.
Cable Length 2 m

Accessories that are included with probe are:Channel Identifier Clip, Sprung Hook, Ground lead, Insulating Tip, Adjusting Tool, Measuring Tip, Sprung Earth Tip.

CS1004 + CS1005 Digital Probe Pods

The CS1004 + CS1005 Digital Probe pod is used to probe up to 8 digital signals. Eight signal and two ground probe clips are included.

Specifications:

Item Value
Attenuation Ratio 1:4
Number of Signal Inputs 8
Probe Description 45 mm Ezy™ Hook, spring probe, 0.4mm probe width
Bandwidth DC to 100 MHz
Rise Time 2 ns
Input Resistance 100 Ω
Input Capacitance Approx 16 pF
Working Voltage -16V to + 20V
Cable Length 1 m from Cleverscope Acquisition Unit to Pod, 150mm from Pod to probe clip

CS1010 Delay Line

A 5nsec delay line to connect the A and B channels together. By using the interleave function in the maths equation builder an effective 200 MSample/sec is available

CS1020 Link Cable

A short cable to connect two Cleverscopes together via the DIG I/O ports. It allows the trigger from one unit to trigger the channels of the other. It does not matter which way round it is used.

CS1030 Differential Probe

The CS1030 Differential probe is a switchable x20, x50 and x200 25 MHz differential probe for making isolated measurements between any two points in a system.

Specifications:

Item Position x 20 Position x 50 Position x 200
Attenuation - 1MΩ 20:1 50:1 200:1
Attenuation - 50Ω 40:1 100:1 400:1
Bandwidth DC to 15 MHz DC to 25 MHz DC to 25 MHz
Working Voltage 140V 350V 1300V
Input Impedance 4 MΩ 1.2 pF between inputs
  2 MΩ 2.3 pF between inputs and ground
Max Diff Voltage 1300V (DC +peak AC)
Max V to Ground 1000 V (DC +peak AC).
Output Impedance 50Ω
Noise 2 mV rms into 50Ω load
CMRR 50/60Hz: >10,000:1
  100Hz: >1,000:1
  1MHz: >300:1
Safety Meets IEC1010-1 Cat 1. EN61010, UL3111
Power One internal 9V PP3 battery or external 6-9V DC.
Size 200 x 55 x 30 mm (plastic case)
Weight 245 gm (plastic case)
Cable Length 1 m

Accessories that are included with the differential probe are:Carry Bag, Instruction Manual, Large Crocodile Clips, Long Grabber Clips, Test leads, BNC-BNC cable, Power supply

CS1031 Differential Probe

The CS1031 Differential probe is a switchable x100, x200, x500 and x1000 50 MHz differential probe for making isolated measurements between any two points in a system.

Specifications:

Item Position x 100 Position x 200 Position x 500 Position x 1000
Attenuation - 1MΩ 100:1 200:1 500:1 1000:1
Attenuation - 50Ω 200:1 400:1 1000:1 2000:1
Bandwidth DC to 25 MHz DC to 50 MHz DC to 50 MHz DC to 50 MHz
Input Impedance 4 MΩ 1.2 pF between inputs
  2 MΩ 2.3 pF between inputs and ground
Max Op Voltage ±650V (DC +peak AC) ±1300V (DC +peak AC) ±3250V (DC +peak AC) ±6500V (DC +peak AC)
Max V to Ground 6500 V (DC +peak AC).
Output Impedance 50Ω
Noise <2 mV rms into 50Ω load
CMRR 50/60Hz: >10,000:1
  100Hz: >1,000:1
  1MHz: >300:1
Safety Meets IEC1010 Cat 1. EN61010, UL3111
Power One internal 9V PP3 battery or external 6-9V DC.
Size 200 x 55 x 30 mm (plastic case)
Weight 245 gm (plastic case)
Cable Length 1 m

Accessories that are included with the differential probe are:Carry Bag, Instruction Manual, Large Crocodile Clips, Long Grabber Clips, Test leads, BNC-BNC cable, Power supply