Downloads
Most files are zipped and you will need to unzip them. In the case of applications and patches, run "setup.exe" to install.
Can not find what you want here? Join our forum and ask the question. Other users may well have an answer for you.
A short list of resources available to you. Click on one to go directly to it or scroll down and read about all of them.
Complete Installation
Cscope 4 Channel Full Install
Win 98 Update
Win98 PI+II Install
Software Update
10 Jun 2013 - 34.5MB
Version v4.672, dated 10 June2013. See Cleverscope Update Instructions pdf in in the update before starting
4.671 New: Includes Frequency Response Analyser tools for switch mode power supplies and other transfer blocks. Includes v2.9 Manual. Note: You MUST Update the firmware to 6463 or later to use this update. Includes ROM Loader 6.7, which automatically finds USB or Ethernet Cleverscopes. A complete history of the software is available hereComplete Installation
08 May 2013 - 40.7 MB
Full v4.671 Installer for Win XP, Vista and Win 7 x32 and x64. Works with both CS328 and CS328A. Only required if you have to re-install. To update an existing installation, use the software update. Extract folder in zip to your hard drive and run setup.exe. Make sure your firmware is 6463 or later.
This package will not work well without an acquisition unit connected. To see how the software works, download the much smaller Evaluation installer with sample files and detailed instructions.
Cscope 4 Channel Full Install
12 Mar 2013 - 38.3 MB
Version 4.250 The Cleverscope 4 channel application is used to link two CS328/CS328A cleverscopes together to act as a 4 channel scope, with 16 digital inputs. The Four channel application pdf tells you what you need to know. This is a full install. Unzip directory to your hard drive. Run setup.exe. Require firmware 6463 or later. Includes Rom Loader in c:\program Files\Cleverscope. See update pdf for firmware update instructions. Now works with either USB or Ethernet interfaces.
Win 98 Update
13 Feb 2008 - 8.8MB
Version v4623 update for Win98 version. Unzip into the program files/cleverscope directory (which overlays old files with new). Brings Win98, ME and NT platform up to same standard as WinXP v4623. Only works with Pentium III and above. There is no need to do a re-install.
Win98 PI+II Install
09 Apr 2006 - 12.3MB
Download this .zip file to install Cleverscope v3.309 on Win98 SE - WinXP systems for Pentium I and II processors. NOTE: These platforms are no longer supported, and this is the last version for Pentium I and II processors. This version is identical to version 3512, with the exception of digital graphs. Digital graphs can be displayed in either normal, or large formats, but the plots do not resize to suit the number of digital inputs selected.
Cleverscope Manual
Using Matlab with Cleverscope
Labwindows Sequential Scope
Protocol Decoding
Silicon Chip October 2008 Cover Story
Integration and filtering
Oscilloscope Review
Vista Installation
Digitize Performance
Sample Signals
Capabilities Tour
Triggering Tour
Digital Pod Details
Guided Tour
CE Conformity
Screen Shots
Application Examples
Frequency Response Analyser
18 Jun 2013 - 1.3 MB
Describes using Cleverscope to carry out Frequency Response (Gain/Phase) evaluation of a switch mode power supply. Switch mode power supplies exhibit large amounts of switching noise which make conventional measurements difficult. The document shows results obtained on a typical flyback converter.
Cleverscope Manual
03 May 2013 - 5.4 MB
Version 2.9 of the Cleverscope Manual. Improved formatting and headings. Additionally covers the Protocol decoder, Maths, Ethernet, Signal Information logging and quite a bit more. 2.9 additions: Charting, Filtering, Matlab, Applications examples.
Using Matlab with Cleverscope
09 Nov 2010 - 300kB
Cleverscope includes 4 processes that can be used to call external Matlab .m functions, considerably extending the capabilities of Cleverscope in analysing waveforms.
The maths Equation builder is used to set up the equation line that calls the Matlab.m functions. This document describes the process in more detail with examples.
Labwindows Sequential Scope
26 Oct 2010 - 9.5MB
Sequential scope example written in NI Labwindows. Also applicable to other text based languages. Based on the example in the 'Sequential Capture' section of Cscope Control Driver vi description.pdf. Includes built exe.
Protocol Decoding
06 Apr 2009 - 2.3Mb
Worked example of using the mixed signal environment to capture a long duration waveform, and decode two protocols - SPI and UART. The zip includes a descriptive PDF, and also 'Trigger - protocol example.apc' that maybe loaded into the Cleverscope application for experimenting with.
Silicon Chip October 2008 Cover Story
10 Oct 2008 - 470kB
Silicon Chip tested Cleverscope and gave a very positive review in their October issue.
Integration and filtering
29 Apr 2008 - 380kB
We have had a few question about using the maths function of cleverscope to do time integrals so here is a step by step guide showing you how to calculate the power consumption of an electronic circuit that draws a variable current.
Oscilloscope Review
07 Apr 2008 - 2.8MB
Performance and User Interface review of Cleverscope and some common oscilloscopes. Reviews the CS328A, Tek TDS2012B, Agilent MSO6012A, Pico 3206/5204, Link Instruments DSO-8502, Bitscope USB310 and TiePie HS3-100.
Vista Installation
24 Aug 2007 - 100kB
Detailed instruction on installing Cleverscope on the Vista operating system.
Digitize Performance
24 Jul 2007 - 0.8 MB
Describes the performance of the 10, 12 and 14 bit digitizers used in the CS328A. Discusses dynamic range, cross talk and noise sources. Displays graphs of typical performance.
Sample Signals
16 Jun 2006 - 1.3MB
This file contains sample full buffer signals for you to look at. Current signals are an SPI DAC being loaded with a new value.
Capabilities Tour
05 Apr 2006 -
This resource discusses Cleverscope capabilities using common applications such as stepper motor control, CCD camera reading and filter transfer response measurement to illustrate each capability.
Triggering Tour
06 Mar 2006 - 0.9MB
This tour shows you how to use the Cleverscope triggering capabilities, with a particular focus on navigating a composite PAL video signal.
Digital Pod Details
20 Feb 2006 - 80kB
Description of digital pod, internal schematic, and information to allow you to replace the digital pod with your own direct connection.
Guided Tour
08 Feb 2006 - 1.4MB
Provides an illustrated guided tour of the Cleverscope application including screen shots and applications.
Screen Shots
26 Jul 2005 - 1.44
Contains a collection of typical screen shots of Cleverscope in action. We have an SPI DAC, E1 telecom data stream, and a video signal.
Application Examples
15 May 2005 - .4MB
This short brief discusses using Cleverscope in ATE and Power supply applications. It also covers Cleverscope self-calibration.
Cscope Control LV2012 V2.6
Cscope Control LV2011 V2.6
Cscope Control LV8.0 V2.6
Cscope Control LV7.1 V2.6
Cscope Control LV2010 V2.5
Cscope Control LV2009 V2.5
Cscope Control LV8.6 V2.5
Cscope Control LV7.0 V2.2
Cscope Control DLL V1
Control Driver Installer
Cscope Control DLL V2.6
02 Apr 2013 - 30.2MB
Version 2.6 Collection of DLL + Simple Scope examples for Labwindows 7.1, Microsoft VS2008 C++, Microsoft VS2008 C#, Microsoft Visual Basic 2008, Borland Delphi 5 and Borland C++ Builder 6. The DLL supports up to 32 connected acquisition units, and USB/Ethernet interfaces. Require v 6463 firmware. New this version - the C++ example includes control of 2 connected units, including external sample clock. The Control Driver DLL description has been significantly expanded. The DLL supports Functions to return serial and version number info, CAU temperature, acquisition status and do calibration. Includes reliability improvements. Works with Win7, 8 x32 and x64 bit. See pdf.
Cscope Control LV2012 V2.6
02 Apr 2013 - 23.3 MB
V2.6 of Labview 2012 Control driver for cleverscope. See the Control Driver VI description pdf. Includes built examples. Supports new calibration system. Use Cscope Control Driver.llb to programmatically initialize, acquire and replay signals using 1-32 Cleverscope Acquisition Units. Includes Function read to return Acquisition Unit serial number, firmware version, frame length, temperature , driver version and sampling status. Able to send and receive data via the Link Port. Includes ability to programmatically calibrate a Cleverscope unit. Improved multi-unit control. You will need v6463 or V5338 firmware loaded into your CS328A or CS328. Works with Win 8
Cscope Control LV2011 V2.6
02 Apr 2013 - 23.3 MB
V2.6 of Labview 2011 Control driver for cleverscope. See the Control Driver VI description pdf. Includes built examples. Supports new calibration system. Use Cscope Control Driver.llb to programmatically initialize, acquire and replay signals using 1-32 Cleverscope Acquisition Units. Includes Function read to return Acquisition Unit serial number, firmware version, frame length, temperature , driver version and sampling status. Able to send and receive data via the Link Port. Includes ability to programmatically calibrate a Cleverscope unit. Improved multi-unit control. You will need v6463 or V5338 firmware loaded into your CS328A or CS328. Works with Win 8
Cscope Control LV8.0 V2.6
02 Apr 2013 - 15.5MB
Version 2.6 Cscope Control VI for Labview 8.0 Includes top level cscope function.vi Supports new calibration system. Use Cscope Control Driver.llb to programmatically initialize, acquire and replay signals using 1-32 Cleverscope Acquisition Units. Includes Function read to return Acquisition Unit serial number, firmware version, frame length, temperature , driver version and sampling status. Able to send and receive data via the Link Port. Includes ability to programmatically calibrate a Cleverscope unit. Includes five top most applications 'Simple Scope', 'Simple Scope 2 unit', 'Bandpass Response' , 'Minimum Scope' and 'Min Sequential Scope' to show you how to use the driver,...
Cscope Control LV7.1 V2.6
02 Apr 2013 - 29.8 MB
V2.6 of Labview 7.1 Control driver for cleverscope. See the Control Driver VI description pdf. Includes built examples. Supports new calibration system. Use Cscope Control Driver.llb to programmatically initialize, acquire and replay signals using 1-32 Cleverscope Acquisition Units. Includes Function read to return Acquisition Unit serial number, firmware version, frame length, temperature , driver version and sampling status. Able to send and receive data via the Link Port. Includes ability to programmatically calibrate a Cleverscope unit. Improved multi-unit control. You will need v6463 or V5338 firmware loaded into your CS328A or CS328. Works with Win 8
Cscope Control LV2010 V2.5
20 Jan 2012 - 21.8 MB
V2.5 of Labview 2010 Control driver for cleverscope. See the Control Driver VI description pdf. Includes built examples. Supports new calibration system. Use Cscope Control Driver.llb to programmatically initialize, acquire and replay signals using 1-32 Cleverscope Acquisition Units. Includes Function read to return Acquisition Unit serial number, firmware version, frame length, temperature , driver version and sampling status. Able to send and receive data via the Link Port. Includes ability to programmatically calibrate a Cleverscope unit.
Cscope Control LV2009 V2.5
20 Jan 2012 - 13.87
V2.5 of Labview 2009 Control driver for cleverscope. See the Control Driver VI description pdf. Includes built examples. Supports new calibration system. Use Cscope Control Driver.llb to programmatically initialize, acquire and replay signals using 1-32 Cleverscope Acquisition Units. Includes Function read to return Acquisition Unit serial number, firmware version, frame length, temperature , driver version and sampling status. Able to send and receive data via the Link Port. Includes ability to programmatically calibrate a Cleverscope unit.
Cscope Control LV8.6 V2.5
12 May 2011 - 17MB
Version 2.5. Cscope Control VI for Labview 8.6.1 Includes top level cscope function.vi Please check your diagram if you have version 2.1 or earlier. Supports new calibration system. Use Cscope Control Driver.llb to programmatically initialize, acquire and replay signals using 1-32 Cleverscope Acquisition Units. Includes Function read to return Acquisition Unit serial number, firmware version, frame length, temperature , driver version and sampling status. Able to send and receive data via the Link Port. Fixes delayed trigger bug and ADC resolution bug. Includes ability to programmatically calibrate a Cleverscope unit. Includes five top most applications 'Simple Scope', 'Simple...
Cscope Control LV7.0 V2.2
18 Jun 2010 - 17.3MB
Version 2.2. Cscope Control VI for Labview 7.0. NOTE: WE have CHANGED the cscope control interface to match the LV 8+ versions. We have added the top level cscope function.vi Please check your diagram. Supports new calibration system. Use Cscope Control Driver.llb to programmatically initialize, acquire and replay signals using 1-32 Cleverscope Acquisition Units. Includes Function read to return Acquisition Unit serial number, firmware version, frame length, temperature and driver version. Able to send and receive data via the Link Port. Fixes delayed trigger bug. Includes five top most applications 'Simple Scope', 'Simple Scope 2 unit', 'Bandpass Response' , 'Minimum Scope' and...
Cscope Control DLL V1
25.3MB
Version 1. Archive. Collection of DLL + Simple Scope examples for Labview 7.1, Labwindows 7.1, Microsoft VS2005 C++, Microsoft VS2005 C#, Borland Delphi 5 and Borland C++ Builder 6 using our older Version 1 Cscope Control DLL. The version 1 DLL does not support multiple connected acquisition units, or the Ethernet interface. We keep it here for compatability with existing projects. It does include an updated DLL that supports firmware 4635, which uses the new Cleverscope Vid/Pid combination. Note that for each envrionment you will have to copy the file Cscope Control Driver.dll from the 'DLL Builds' directory to the appropriate sub directories. We have done this to save download...
Control Driver Installer
27MB
Version 2.4 of the Control Driver Installer. Installs the environment required to run the Cscope Control DLL or vi to a PC that has never had Cleverscope loaded. See the instructions in 'Cleverscope Control Driver install instructions.pdf'

